Code Applied by the app plumb.hanger.copper

Hanger spacing for copper tube

How far apart copper tube may be supported — 6 feet horizontal at 1-1/4 inch and smaller, 10 feet at 1-1/2 inch and larger, 10 feet vertical.

The rule, as the app applies it
WhenThe app uses
horizontal, 1-1/4 in and smaller6 ft
horizontal, 1-1/2 in and larger10 ft
vertical10 ft
Source
IPC · 308.5, Table 308.5 · read the public text
Editions checked
2018 · 2021
Used by
Child counts Bid Check
Amendments

No state or local amendment to this rule is on file. Not on file means the model code as written — check your jurisdiction.

A model code the authority having jurisdiction adopts.

Copper carries its own weight better than plastic, so the spacing is wider and steps up with size. A 60-foot run of 3/4-inch copper is ten hangers; the same run in 2-inch is six.

What the app does with it

A line type whose name says copper (or Cu, or Type L / K / M) and a size is offered Hanger · 1 per 6 ft (10 ft at 1-1/2 in and larger) under Child counts, stamped with this rule; Bid Check's Hangers on every supported run row warns while a copper type has none. The count runs on the run's tally length, drops included — a riser is counted at the horizontal spacing, never looser than the code.

Cited by section, not reprinted: the code text belongs to its publisher. Company practice is not a rule here — it lives with your pricing. Updated Sep 9, 2026.