Hanger spacing for PVC pipe
How far apart PVC pipe may be supported — 4 feet horizontal, 10 feet vertical.
| When | The app uses |
|---|---|
| horizontal | 4 ft |
| vertical | 10 ft |
- Source
- IPC · 308.5, Table 308.5 · read the public text
- Editions checked
- 2018 · 2021
- Used by
- Child counts Bid Check
- Amendments
No state or local amendment to this rule is on file. Not on file means the model code as written — check your jurisdiction.
A model code the authority having jurisdiction adopts.
PVC drainage and vent pipe is supported every 4 feet horizontally, whatever the size, and every 10 feet on a stack. That makes hanger count on a waste line one of the easiest derived quantities on a plumbing bid — length divided by four, rounded up per run.
What the app does with it
A line type whose name says PVC, ABS or DWV is offered Hanger · 1 per 4 ft under Child counts, stamped with this rule; Bid Check's Hangers on every supported run row warns while such a type has none. CPVC is a different row of the table and is not matched. The count runs on the run's tally length, drops included.
Cited by section, not reprinted: the code text belongs to its publisher. Company practice is not a rule here — it lives with your pricing.